Goomalling Shire Water Reuse Treatment Plant
- Aug 14
- 2 min read
Updated: Aug 18
Goomalling, Western Australia | 2016–2017 | Water Reuse Treatment
Service Capacity: 390 m³/day
Treatment System: Containerised Water Reuse Treatment Plant | 250 kL Water Storage
Treatment Process: 20-Micron Automatic Backwash Filtration | Chlorination | REDOX/ORP Control | Recirculation Pumping

THE CHALLENGE
Goomalling Shire Council required a water reuse treatment plant capable of treating 390 m³/day of reclaimed water for reuse.
THE SOLUTION
Aquasol designed and supplied a 390 m³/day containerised water reuse treatment plant, incorporating automatic backwash filtration, chlorine dosing, REDOX/ORP control, pumping and 250 kL of water storage.
THE RESULTS
The project delivered a dedicated water reuse treatment system combining filtration, disinfection, pumping and storage for reclaimed water reuse.
KEY HIGHLIGHTS:
390 m³/day water reuse treatment plant
Containerised treatment system
20-micron automatic backwash filtration
Liquid chlorine dosing
REDOX/ORP chlorine control
Recirculation pumping
250 kL water storage
Process instrumentation and controls
Reclaimed water reuse
System design and equipment supply
Technical documentation
Supply coordination
Project delivered in 2016–2017
Goomalling, Western Australia
ABOUT THE CLIENT:
Goomalling Shire Council was the client for this water reuse treatment project in Goomalling, Western Australia.
The project involved the design and supply of a 390 m³/day water reuse treatment plant for reclaimed water reuse, incorporating filtration, disinfection, pumping, storage and process controls.
CHALLENGE: TREATING RECLAIMED WATER FOR REUSE
The project required a dedicated treatment system for reclaimed water reuse, with a design treatment capacity of 390 m³/day.
The system needed to incorporate filtration and disinfection together with the pumping, storage and control equipment required to support the treatment process.
A further requirement was to provide the treatment system in a containerised configuration, bringing the treatment equipment together into a coordinated system.
SOLUTION: CONTAINERISED WATER REUSE TREATMENT
Aquasol designed and supplied a 390 m³/day containerised water reuse treatment plant for Goomalling Shire Council.
The treatment system incorporated 20-micron automatic backwash filtration followed by liquid chlorine dosing and REDOX/ORP control for disinfection management.
The system also incorporated:
Recirculation pumping
250 kL water storage
Process instrumentation
Process controls
Water filtration
Chlorine dosing
Aquasol's services included system design, equipment supply, technical documentation and supply coordination.

RESULTS: 390 M³/DAY RECLAIMED WATER TREATMENT
The project delivered a 390 m³/day water reuse treatment plant for reclaimed water reuse in Goomalling.
The completed system combined automatic backwash filtration, chlorine dosing, REDOX/ORP control, recirculation pumping and 250 kL of water storage within a containerised treatment solution.
Aquasol provided the system design, equipment supply, technical documentation and supply coordination for the project.
LOOKING FOR A WATER REUSE TREATMENT SOLUTION?
Aquasol designs and supplies water reuse treatment systems incorporating filtration, disinfection, pumping, storage and process controls.
Talk to Aquasol about a water reuse solution designed around your site's treatment requirements.